PERFORMANCE & SPECIFICATIONS
SPECIFICATIONS
Power supply required..............................................................................................................................115V, 60 HZ.
Liquid temp. range...................................................................................................................................32°F to 70°F(0°-21°C)
Individual branch circuit required (min.)...................................................................................................15 Amps
Discharge.................................................................................................................................................1-1/2" FNPT
NOTE: Do not reduce size of discharge pipe or hose below 1-1/4" diameter. If discharge is too small, pump will overheat and fail prematurely.
PERFORMANCE
SERIES
HP
MS50V10-R
1/2
ELECTRICAL & SWITCH SPECIFICATIONS
SERIES
HP
MS50V10-R
1/2
6
All manuals and user guides at all-guides.com
GPH (LPH) at total feet (m) of lift
0'
5'
(0.0m)
(1.5m)
Capacity Gallons(L)/Hour
4500
3960
(17034)
(15000)
INDIVIDUAL
MOTOR FULL
BRANCH CIRCUIT
LOAD AMPS
REQ. (AMPS)
4.1
15A 115 VAC
10'
15'
(3m)
(4.6M)
3360
2640
(12720)
(9994)
SWITCH SETTING IN INCHES WATER
LEVEL FOR:
AUTOMATIC SWITCH
TYPE
ON
Vertical Switch
7-1/2"
NO FLOW AT
20'
HEIGHT SHOWN
(6.1M)
BELOW IN FEET
(METERS)
1020
25
(3861)
(7.6)
OFF
3"
MY999-R (06-20-20)