indicator on the connector (if fitted) has not
been deployed.
Function Test: Pull line sharply to engage
brakes and ensure device locks before each
and every use. Pull out line to ensure that it
pays out and retracts smoothly and completely.
Labelling: Ensure product labelling is present
and entirely legible. Ensure product age has
not exceeded the stated lifespan.
Thorough Inspection:
Thorough inspection must be conducted and
recorded at least every 12 months or every
3 months if used in offshore or corrosive
environments.
A
thorough
inspection
of
Guardian RTFAs requires the removal of
equipment
housing,
therefore
thorough
inspection may only be carried out by the
manufacturer
or
manufacturer
approved
agent, this inspection may involve disassembly
and repair. In addition, local regulations in
regard to inspection must be followed. CP to
inspect and initial. Separate inspection logs
must be used for each individual piece of
equipment. All inspection records must be
made visible and available to all users at all
times. If equipment fails thorough inspection,
it must be immediately removed from service
and discarded or repaired. During inspection,
consider all applications and hazards the
equipment has been subjected to. Ensure that
device certification is current before use, this
device must only be repaired by a competent
person authorised by the manufacturer.
The FAB3W does not require disassembly to
conduct thorough inspection, only a pre-use
inspection/function check before each use
and an inspection by a competent person
other than the user at least every 12 months or
every 3 months if used in offshore or corrosive
environments.
22
85627 REV. E