Prepare Built-In Oven

NOTE: The IKEA
®
Column Cabinet is available for installation but
not required. The oven may also be installed into custom cabinets.
1. Decide on the final location for the oven.
WARNING
Excessive Weight Hazard
Use two or more people to move and install oven.
Failure to do so can result in back or other injury.
2. To avoid floor damage, set the oven onto cardboard prior to
installation. Do not use oven door handle or any portion of the
front frame or trim for lifting.
3. Remove the shipping materials and tape from the oven.
4. Remove the hardware package from inside the bag containing
literature.
5. Remove and set aside racks and other parts from inside the
oven.
6. Move oven and cardboard close to the oven's final location.

Remove Oven Door

IMPORTANT: Use both hands to remove oven doors.
1. Open oven door all the way.
2. Flip up the hinge latch on each side.
3. Close the oven door as far as it will shut.
4. Lift the oven door while holding both sides.
Continue to push the oven door closed and pull it away from
the oven door frame.
4

INSTALLATION INSTRUCTIONS

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 12 gauge copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This oven is manufactured with a neutral (white) power supply
wire and a cabinet-connected green (or bare) ground wire twisted
together.
1. Disconnect power.
2. Feed the flexible cable conduit from the oven through the
opening in the cabinet.
3. Remove junction box cover if it is present.
4. Install a UL listed or CSA approved conduit connector to the
junction box.
A
A. UL listed or CSA approved conduit connector
5. Route the flexible cable conduit from the oven to the junction
box through a UL listed or CSA approved conduit connector.
6. Tighten screws on conduit connector.
7. See "Electrical Connection Options Chart" to complete
installation for your type of electrical connection.
Electrical Connection Options Chart
If your home has:
4-wire
½"
(1.3 cm)
3-wire
½"
(1.3 cm)
Go to section:
4-wire Cable from Home
Power Supply
3-wire Cable from Home
Power Supply