MADE IN FRANCE
MAINTENANCE
General recommendations
• It is recommended to change the cooling liquid every two years, otherwise you may damage the Powerduction's lance.
• It is essential that the maintenance of the product is performed by qualified, authorised staff, that is fully aware of the
recommendations outlined in this manual.
• Never clean, lubricate or perform maintenance on the product when it's being used.
• Before any maintenance work, set the On / Off switch to « 0 » to switch off the machine, .then disconnect it it from
the mains power supply to prevent any electrical shock or other risks resulting from improper handling.
• Do not wear rings, watches, jewellery, hanging clothes (e.g. ties), torn clothes, scarves, unbuttoned or unzipped
jackets, or anyhting that could get caught during the operation of the machine
• Rather wear clothing specifically designed for the prevention of accidents, such as: non-slip shoes, anti-noise helmets,
protective goggles, safety shoes, etc ...
• Never use petrol or flammable solvents to clean the product. Prefer the use of water and, if necessary, non toxic com-
mercial solvents.
• After maintenance, always put and secure the metal covers back on, before switching the machine on.
• The ferrite on inducer can be replaced if damaged.
To replace it, you must :
- Remove the protection,
- Remove the ferrite on copper with a heat gun to facilitate the removal of the resin,
- Clean copper,
- Glue the ferrite with the specific resin,
- Reposition the ferrite with its protection,
- Waiting for the complete setting of the adhesive before using the inductor.
ACCESSORIES
Inductor
056862
OPTIONS
Inductor
056886
28
POWERDUCTION 37LG - 39LG - 50LG
39LG - 50LG
Ferrite
20°
053823
Gallows - Cable carrier
39LG - 50LG
Ferrite
90°
053823
053458
Glue Stick-Power Bi-component Epoxy 150 ° C
052284
054851
Protection
056909
Protection
SPOT 800 + Gallows
056909
056916
051331 + 052284
EN
37LG
Inductor
058927
37LG

Publicité

loading

Ce manuel est également adapté pour:

Powerduction 37lgPowerduction 50lg