Télécharger Imprimer la page

Danby DAC080B8IWDB-6 Manuel Du Propriétaire page 11

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS
LOCATION
This air conditioner is designed to fi t inside a
standard double-hung window with opening widths
of 23.6 - 38.8" (60 - 98.5 cm).
The lower sash must open suffi ciently to allow a
clear vertical opening of 13.8" (35 cm).
This air conditioner is not designed for vertical,
slider type windows or "through the wall"
installation.
Ensure that the window and frame are structurally
sound and free from dry or rotted wood.
Install the air conditioner on a side of the building
which favors more shade than sunlight. If the
appliance must be in direct sunlight, it is advisable
to provide a shade awning to ensure effi cient
functioning.
Do not install the appliance where leakage of
combustible gas is suspected.
This air conditioner is designed to evaporate
condensation under normal conditions. Under
extremely hot or humid conditions, excess
condensation may overfl ow to the outside. The air
conditioner should be installed where condensation
cannot drip on pedestrians or neighboring
properties.
Provide suffi cient clearance around the appliance
to allow ample air circulation. The rear of the
appliance should be outdoors, it should not be in a
garage or another room. Keep the appliance away
from obstacles and at least 11.8" (30 cm) above the
ground. Ensure that curtains and other obstructions
do not block air fl ow.
The side louvers and the rear of the air conditioner
must have at least 11.8" (30 cm) of space for
proper air circulation.
A. Interior wall
B. Exterior wall
C. Inner window sill
D. Offset
E. Seal foam
Wooden Window Sills
D
C
A
Vinyl-Clad Window Sills
D
C
A
10
E
23.6" to 38.8"
(60 cm to 98.5 cm)
13.8" min
(35 cm)
B
E
23.6" to 38.8"
(60 cm to 98.5 cm)
B
13.8" min
(35 cm)

Publicité

loading

Ce manuel est également adapté pour:

Dac100b8iwdb-6