COMPRESSOR 1.1HP - 750W - 8L
The numbers in the following text correspond with
the pictures at page 1 - 4.
Read the operating instructions carefully
before using this device. Familiarise
yourself with its functions and basic
operation. Service the device as per the
instructions to ensure that it always
functions properly. The operating
instructions and the accompanying
documentation must be kept in the
vicinity of the device.
Contents
1. Machine details
2. Safety instructions
3. Use
4. Maintenance
1. MaCHinE dEtaiLS
technical specifications
Voltage
Frequency
Capacity
Idling speed
IP Class
Tank contents
Air intake
Max. outlet pressure
Sound power level
The value of the noise level may rise from 1 to 10
dB(A) as a function of the environment in which
the compressor will be installed.
Product information
Fig. A
1 Cover
2. Handle
3. Switch
4. Automatic stop
5. Pressure regulator
6. Quick coupler (regulated outlet pressure)
7. Pressure gauge (pressure regulator)
8. Pressure gauge (tank)
9. Safety valve
10. Pressure pipe
11. Air filter
12. Oil cap
13. Oil level inspection glass
14. Drain cock
15. Overload switch
2. SafEty inStRuCtiOnS
Explanation of symbols
230 V~
50 Hz
1.1 hp (750 W)
2850/min
IP 20
Special safety instructions
• W arning! The compressor may only be used in
8 litre
suitable rooms (with good ventilation and an
118 l/min
ambient temperature from 0°C to +40°C).
8.0 Bar
• C heck that the tank is fully decompressed
before connections with the tank are unscrewed.
93 dB (A)
• I t is prohibited to make holes in, or welds to, or
purposely to distort the compressed air tank.
• D o not perform any actions on the compressor
without first having taken the plug out of the
plug socket.
• D o not aim water jets or jets of flammable
liquids at the compressor.
• D o not place flammable objects near the
compressor.
• S witch the switch (3) to the "0" position (OFF)
during dwell time. (fig. 11)
• N ever aim the air jet at persons or animals
(fig. 20).
• D o not transport the compressor with the tank
Denotes risk of personal injury, loss of life
or damage to the tool in case of non-
observance of the instructions in this
manual.
Risk of electric shock.
Caution: the compressor could start
automatically in case of a black-out and
subsequent reset
Wear ear protection.
Sound power level
5