WINTER STORAGE
NOTICE
You must protect your unit from freezing temperatures.
• Failure to do so will permanently damage your pump and
render your unit inoperable.
• Freeze damage is not covered under warranty.
To protect the unit from freezing temperatures:
1. Empty cleaning tank as follows:
a.
Disconnect hose connected to injection fitting on
pump. Place end of hose into suitable container.
b. Rotate detergent shut-off valve to "On" position and
open the tanks cover. Gravity will empty tank
contents into container.
c.
Reconnect hose to injection fitting on pump. Add
0.5 quart (0.5 l) of clean fresh water to cleaning
tank and close tanks cover.
2. Flush cleaning tank by turning its detergent shut-off
valve to "On" position and run pressure washer with
black nozzle. Flush until tank is empty. Turn detergent
shut-off valve to "Off" position.
3. Follow steps 2-5 in the previous section After Each Use.
4. Use PumpSaver, available at Sears to treat pump. This
minimizes freeze damage and lubricates pistons and
seals.
5. If PumpSaver is not available, connect a 3-foot (1 m)
section of garden hose to water inlet adapter. Pour
RV–antifreeze (antifreeze without alcohol) into hose. Pull
recoil handle twice. Disconnect 3-foot (1 m) hose.
6. Store unit in a clean, dry area.
LONG TERM STORAGE
If you do not plan to use the pressure washer for more than
30 days, you must prepare the engine and pump for long
term storage.
Protect Fuel System
Fuel Additive:
Fuel can become stale when stored over 30 days. Stale fuel
causes acid and gum deposits to form in the fuel system or
on essential carburetor parts. To keep fuel fresh, use Briggs
& Stratton FRESH START™ fuel stabilizer, available as a
liquid additive or a drip concentrate cartridge.
There is no need to drain gasoline from the engine if a fuel
stabilizer is added according to instructions. Run the engine
for 2 minutes to circulate the stabilizer throughout the fuel
system. The engine and fuel can then be stored up to
24 months.
All manuals and user guides at all-guides.com
STORAGE
If gasoline in the engine has not been treated with a fuel
stabilizer, it must be drained into an approved container. Run
the engine until it stops from lack of fuel. The use of a fuel
stabilizer in the storage container is recommended to
maintain freshness.
Change Oil
While engine is still warm, drain oil from crankcase. Refill
with recommended grade. See Changing Engine Oil.
Oil Cylinder Bore
Protect Pump
To protect the pump from damage caused by mineral
deposits or freezing, use PumpSaver to treat pump. This
prevents freeze damage and lubricates pistons and seals.
NOTE: PumpSaver is available as an optional accessory. It is
not included with the pressure washer. Contact your local
Sears service center to purchase PumpSaver.
You must protect your unit from freezing temperatures.
• Failure to do so will permanently damage your pump and
• Freeze damage is not covered under warranty.
To use PumpSaver, make sure the pressure washer is turned
off and disconnected from supply water. Read and follow all
instructions and warnings given on the PumpSaver container.
Other Storage Tips
1. DO NOT store fuel from one season to another unless it
2. Replace fuel container if it starts to rust. Rust and/or dirt
3. Cover unit with a suitable protective cover that does not
• DO NOT place a storage cover over a hot pressure washer.
• Let equipment cool for a sufficient time before placing the
4. Store unit in a clean and dry area.
21
Remove spark plug and pour about 1/2 ounce (15 ml) of
clean engine oil into the cylinder.
Install spark plug and pull starter handle slowly to
distribute oil.
NOTICE
render your unit inoperable.
has been treated as described in Protect Fuel System.
in fuel can cause problems if it's used with this unit.
retain moisture.
WARNING
Storage covers can be flammable.
cover on the equipment.

Publicité