3.
Before connecting garden hose to water inlet, inspect
inlet screen (A). Clean screen if it contains debris or have
it replaced if damaged. DO NOT run pressure washer if
inlet screen is damaged or missing.
4. Run water through garden hose for 30 seconds to flush
it of debris. Turn off water.
IMPORTANT: DO NOT siphon standing water for the water
supply. Use ONLY cold water (less than 100°F (38°C)).
5. Connect garden hose (not to exceed 50 feet (15.24 m) in
length) to water inlet. Tighten by hand.
NOTICE
Using a One Way Valve (vacuum breaker or check valve) at
pump inlet can cause pump or inlet connector damage.
• There MUST be at least ten feet of unrestricted garden hose
between the pressure washer inlet and any device, such as a
vacuum breaker or check valve.
• Damage to equipment resulting from failure to follow this
instruction will void warranty.
All manuals and user guides at all-guides.com
6. Turn ON water, point gun in a safe direction and squeeze
• Always wear safety goggles when using this equipment or in
A
• Before starting the pressure washer, be sure you are wearing
• NEVER substitute safety glasses for safety goggles.
Checklist Before Starting Engine
Review the unit to ensure you have performed all of the
following:
1. Be sure to read Safety Rules and Operation sections
2. Make sure handle is in place and secure.
3. Check that oil has been added to proper level in engine
4. Add proper fuel to fuel tank.
5. Check for proper hose connections (high pressure and
6. Provide proper water supply (not to exceed 100°F
10
trigger to purge pump system of air and impurities.
WARNING
Risk of eye injury.
Spray can splash back or propel objects.
vicinity of where equipment is in use.
adequate safety goggles.
before using the cleaning system.
crankcase.
water supply) and that there are no kinks, cuts, or