Main and absolute filter disassembly and
replacement
When the machine is used to vacuum hazardous
substances, the filters become contaminated, therefore:
Work with care and avoid spilling the vacuumed
dust and/or material;
place the disassembled and/or replaced filter in a
sealed plastic bag;
close the bag hermetically;
dispose of the filter in accordance with the laws
in force.
Filter replacement is a serious matter. The filter must be
replaced with one of identical characteristics, filtering
surface and category.
Otherwise the machine will not operate correctly.
Before proceeding with these operations, turn off the
machine and remove the plug from the power socket.
Before performing these operations, clean the filter
as described in the "Maintenance, cleaning and
decontamination" paragraph.
Take care not to raise dust during this operation. Wear
a P3 mask and other protective clothing plus protective
gloves (PPE) suited to the hazardous nature of the dust
collected, refer to the laws in force.
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use gloves
that provide protection against mechanical risks (EN
I
388) with a level of protection CAT. II.
GB
Do not use the Class H filter again after having removed
it from the machine.
F
D
E
C343
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
Primary filter replacement, for machines equipped
with manual cleaning system
Use lever (2) to release vacuum unit (1) then pull it up and
out of the vacuum cleaner.
Lift the filter, unscrew the clamp and remove the ring.
Cut the clamps (10) and detach the cage from the filter.
Fit the new filter and secure it in the cage with special
clamps.
Dispose of the old filter according to the laws in force.
After replacing the filter in the cage (3), install it in the
container again.
Reassemble vacuum unit (1) making sure filter cage (3)
fits into shaped housing (5) of the filter shaker.
Turn the power switch on and the vacuum unit will self-
centre automatically.
Use locking lever (2) to lock the vacuum unit in place.
Primary filter replacement, for machines equipped
with automatic cleaning system
Use lever (2) to release vacuum unit (1) then pull it up and
out of the vacuum cleaner.
Lift the filter, unscrew the clamp and remove the ring.
Cut the clamps (10) and detach the cage from the filter.
Fit the new filter and secure it in the cage with special
clamps.
Dispose of the old filter according to the laws in force.
After having replaced and fitted the filter in the cage, insert
filter shaker cage (4) in the shaped seat (5) of the filter
shaker.
Position the manual filter shaker knob (1) in the middle.
Reassemble vacuum unit (2) complete with cage and
filter, in the vacuum container.
Check the filter shaker works properly and if necessary
adjust the position of the filter cage by turning the vacuum
unit.
Use locking lever (3) to lock the vacuum unit in place.
14
Figure 11
Figure 12