TRANSMITTERS OF THE RANGE
DEV-T1
Using a DEV-T1 series transmitter it is possible to activate the
transmitter storage.
P1
P2
P3
P1
UP button input
P2
STOP button input
P3
DOWN button input
P4
Code storage stage activated
N
Power supply neutral
L
Power supply phase
Pressing the three buttons in combination allows to activate the
following functions on the control unit:
P2 + P1 - Sun sensor activated
P2 + P3 - Sun sensor disabled
P1 + P3 - STOP command
NOTE: you must hold the buttons pressed until the control unit
signals it has received the command by running the motor or
activating the relays.
All manuals and user guides at all-guides.com
P4
N
L
STORAGE OF THE TRANSMITTERS
DEV-T1
Transmitters may be memorised in two different ways:
1. By means of the MOT push-button
2. By means of the transmitter (P4 push-button)
m
WARNING: The first transmitter has to be memorized
following the procedure (storage by push-button MOT)
STORAGE BY MEANS OF THE
MOT PUSH-BUTTON
1. Press and then release the MOT key on the control unit: the
MOT1 LED lights up.
2. Transmit using the P4 button of the remote control device
until the motor starts.
3. Release the button on the remote control device.
4. Press the UP button of the motor raised the shade, or the
DOWN button if the motor lowered the shade.
5. Programming completed.
m
WARNING: The first transmitter memorised determines the
direction of movement of the motor. If the logic is altered, it is
necessary to delete all codes stored and repeat the previous steps
(see paragraph DELETING TRANSMITTERS).
STORAGE BY MEANS OF THE
P4 PUSH-BUTTON
To add another transmitter TX2 to the control unit it is
necessary to use a DEV-T1 previously stored (TX1) and
proceed as follows:
1. Press and keep pressed for about 5 seconds the key P4 of the
TX1 until the motor starts to move.
2. Release the key P4, the motor stops.
3. Press the key UP or DOWN of the TX2: the transmitter is
stored with the same logic of the TX1.
DELETING ALL TRANSMITTERS
MEMORISED
1. Remove the power supply to the control unit.
2. Press and hold the MOT key while power is restored to the
control unit.
3. After 2 seconds, release the MOT key: the MOT1 LED flash for
one second to indicate the delete process has been successful.
- 29 -