PROGRAMMING OF THE LEVEL OF
INTERVENTION OF THE SUN SENSOR
(SWITCH 8)
m
WARNING: to make the awning open the sun sensor has
to detect a value higher then the set threshold value for at least 8
minutes. To make it close, the sensor has to detect a value lower
then the set threshold value for at least 8 minutes.
Interruptions of light (due to clouds) shorter than a minute are
not detected, while the 8-minute timer is set at zero when longer
than one minute.
To set the level of intervention of the sun sensor it is
necessary to use a remote control previously stored and
proceed as follows:
1. Multichannel transmiter only: press several times the button
SELC of the transmitter until shown by leds the channel
stored.
2. Position the roll-up shutter at the mid-height
3. Set on ON the switch 8 of the transmitter.
4. Press and keep pressed (for 5 about seconds) the button PROG
of the transmitter until the motor moves jerkily in both the
ways showing that it enters the storing.
5. The number of jerks made by the motor corresponds to the
level currently set:
1 jerk
= level 1 = 2 Klux
2 jerks = level 2 = 5 Klux
3 jerks = level 3 = 10 Klux (default)
4 jerks = level 4 = 20 Klux
5 jerks = level 5 = 40 Klux
6. To increase the level press button UP, to decrease it press
button DOWN.
7. As soon as the control unit receives the control, it shows the
new level moving the motor with the corresponding number
of jerks.
8. To exit the programming press STOP: the motor displays again
the set level and exits.
9. Set on OFF the switch 8
To disabling the sun sensor proceed as follows:
1. Multichannel transmiter only: press several times the button
SELC of the transmitter until shown by leds the channel
stored.
2. Position the roll-up shutter at the mid-height
3. Press the key STOP and immediately after the key DOWN
(keeping pressed the key STOP) until the motor moves for
about one second in both the ways, indicating that the
procedure has been finished.
To enable again the sun sensor it is enough to repeat
the procedure above using the key UP instead of the key
DOWN.
All manuals and user guides at all-guides.com
PROGRAMMING OF THE LEVEL OF
TEMPERATURE (SWITCH 10)
The temperature can be set on 5 levels, under which the sun
sensor must not open the awning, even if the light intensity has
exceeded the level set by switch 8.
This function is particularly useful in Countries with wintry
weather, where sunny but very cold days are frequent. In this case,
it is not necessary to open the awnings, to let the sun warm the
inner rooms.
To set the level of temperature it is necessary to use a
remote control previously stored and proceed as follows:
1. Multichannel transmiter only: press several times the button
2. Position the roll-up shutter at the mid-height
3. Set on ON the switch 10 of the transmitter.
4. Press and keep pressed (for 5 about seconds) the button PROG
5. The number of jerks made by the motor corresponds to the
6. To increase the level press button UP, to decrease it press
7. As soon as the control unit receives the control, it shows the
8. To exit the programming press STOP: the motor displays again
9. Set on OFF the switch 10
- 22 -
SELC of the transmitter until shown by leds the channel
stored.
of the transmitter until the motor moves jerkily in both the
ways showing that it enters the storing.
level currently set:
1 jerk
= level 1 = sensor disabled (default)
2 jerks
= level 2 = 0°C
3 jerks
= level 3 = 5°C
4 jerks
= level 4 = 10°C
5 jerks
= level 5 = 15°C
button DOWN.
new level moving the motor with the corresponding number
of jerks.
the set level and exits.