Complete Installation - KitchenAid UXI0600DYS Instructions D'installation Et Guide D'utilisation Et D'entretien

Système de ventilation rétractable (clapet) de 30" (76,2 cm) et 36" (91,4 cm) – aspiration par le bas
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NOTE: The downdraft vent system is supplied with a 3
10" (8.3 cm x 25.4 cm) back-draft damper and a 6" (15.2 cm)
round vent transition with damper. Refer to "3
x 25.4 cm) Back-Draft Damper" or "6" (15.2 cm) Round Vent
Transition with Damper," depending upon the type of venting you
are using.
3
/
" x 10" (8.3 cm x 25.4 cm) Back-Draft Damper
1
4
1. Attach the 3¼" x 10" (8.3 cm x 25.4 cm) back-draft damper
to the vent opening in the blower motor box, using three
3.5 x 9.5 mm screws.
B
A. 3.5 x 9.5 mm screws
B. 3¼" x 10" (8.3 cm x 25.4 cm) back-draft damper
6" (15.2 cm) Round Vent Transition with Damper
1. Attach the 6" (15.2 cm) round vent transition to vent opening
(left- or right-side venting only is recommended) using two
3.5 x 9.5 mm screws.
A
A. 3.5 x 9.5 mm screws
B. 6" (15.2 cm) round vent transition with damper

Complete Installation

(Interior-Mounted Motor)
/
" x
1
4
1
/
" x 10" (8.3 cm
4
A
A
B
2. Remove four screws attaching the terminal box cover.
A
A. Terminal box cover
3. Determine which direction (front or rear) the home power
supply cable will enter the terminal box. Remove the
appropriate knockout from the front or rear panel and install a
1/2" (13 mm) UL Listed or CSA approved conduit connector.
4. Using two or more people, insert the downdraft vent into the
countertop cutout. Position downdraft vent so it is centered
in the cutout with the rear flange over the edge of the cutout
and the rear of the vent box against the edge of the cutout.
G
A. Rear flange of downdraft vent
B. Edge of cutout in countertop
C. Rear of downdraft vent
D. Cabinet back
A
B
C
D
E
F
E. Lower support leg
F. Cabinet floor
G. Countertop
15