6.1 Cleaning the silicone covered rollers
The rollers must be cleaned regularly to prevent a build-up of residue. This may eventually damage
the rollers.
Use a damp lint-free cloth to remove dust and other dirt.
Difficult stains can be removed with the aid of isopropyl alcohol (IPA) and a clean lint-free cloth.
Do not pour isopropyl alcohol directly on the machine.
WARNING:
ISOPROPYL ALCOHOL IS VERY FLAMMABLE! THE FLASH POINT OF IPA IS
11°C (51.8°F). THE SELF-IGNITION TEMPERATURE IS 400°C (752°F).
6.2 Preventive maintenance
SEAL® machines are designed so they need little (preventive) maintenance in addition to the
cleaning.
The following checks have to be performed:
Auto-grip shafts with blocking cords.
6.2.1 Auto-grip shafts
Check the auto-grip mechanism on each shaft.
The distance (d) between the rubber cord and flat edge should be 8 ± 2.5 mm minimum.
d
A
Figure 20: Auto-grip shaft
If not, correct as follows:
Loosen the clamp (2) with the screw (1) until the cord is free on one side.
Shorten the cord by cutting approximately 10 mm (0.4 in.) off.
Put the end of the cord back underneath the clamp (2).
Secure it by tightening the screw (1).
3
2
1
B