Tracing Energized and De-energized Wires
Set-up:
1
Test Leads for
separate neutral connection
Proper connection with separate neutral
1. Plug the green and red test leads to the Transmitter.
2. Connect the red test lead to the wire being traced,
Energized or De-energized. For receptacles, make
sure to connect the test lead to the line/phase wire.
The signal will only be transmitted between the
load-side to which the Transmitter is connected and
the source of power.
3. Connect the green wire to a separate neutral wire
at the breaker/fuse or at a connection point as close
to the breaker/fuse as it is possible.
Note: Please make sure that line/phase wire and
separate neutral are connected to the same RCD,
otherwise the RCD will trip.
Set-up:
2
Transmitter
Transmitter
indicator showing
signal in
HIGH mode
1. Turn on the Transmitter.
2. Verify that the test leads are properly connected; the
red LED voltage status light should be on for circuits
with voltage above 30 V AC/DC, and it should be off
for De-energized circuits below 30 V AC/DC.
3. HIGH signal mode is automatically activated
when the Transmitter is turned on.
2
Beha-Amprobe
®
Receiver:
Tracing Mode
Use this mode to easily follow the direction of a wire.
Signal not detected
1. Turn on the Receiver.
Tracing mode is automatically activated.
2. Scan the target area with the Tip Sensor to find the
highest signal level, then begin tracing the detected
wire. Increase or decrease sensitivity of the Receiver
by pressing + or - on the keypad as necessary.
Tip groove
TIP: Align groove on the Tip Sensor with wire
direction for best results while tracing Energized
wires. Signal may be not detected if not properly
aligned. To verify wire direction, periodically
rotate the Receiver 90 degrees. Signal strength
will be the highest when wire is aligned with the
Tip Sensor groove.
Signal detected