Télécharger Imprimer la page

Power Fist 8146979 Mode D'emploi page 4

Publicité

Les langues disponibles

Les langues disponibles

maIntenance & StoraGe
always ensure that the pump is operating with adequate water supply. Periodically shut off the power supply
and check the pump for debris lodged in the intake grill. The intake grill may be removed and cleaned by removing
the screws underneath the pump housing. The pump's motor is completely sealed in the motor housing and does
not require regular service. Disassembly of the motor housing or modification or removal of the power cords voids
your warranty. The power cord is non-replaceable. Make sure the pump is dry and clean before storing. Retain the
original packaging for the purpose of storing your pump. Always store your pump in a cool dry place. Never store
it while it is still connected to power. Do not stress the cord by wrapping it too tightly around the pump, as it could
cause the cord to eventually fray and break down. DO NOT store in water. When re-using the pump, please re-read
the instructions.
Problem
Pump does not start.
Pump operates but pumps very little or
no water.
Pump has stopped.
Pump Handle
Intake Grill
(Keep clean)
For any technical questions, please call 1-800-665-8685
trouBLeSHootInG
Possible causes
Blown fuse/circuit breaker has
tripped.
Low line voltage.
Defective motor.
Low line voltage.
Debris caught in impeller.
Worn or defective parts.
Lower than operating water level has
caused pump to overheat.
PartS IdentIfIcatIon
Discharge Outlet
Motor Housing
(Sealed)
Float Switch
Pump Base
N
OTE: DO NOT OPEN THE MOTOR HOUSING
4
8146979 / 8146953
suggested solution
If fuse has blown, replace with new fuse/
reset circuit breaker.
Check size of wiring from main switch on
property/contact your local power authority.
Contact Princess Auto at 1-800-665-8685.
Check size of wiring from main switch on
property/contact your local power authority.
Contact Princess Auto at 1-800-665-8685.
Contact Princess Auto at 1-800-665-8685.
Increase operating water level or pump
cooler water.
Discharge Outlet
Pump Base
(Keep clean)
!
Pump Handle
Intake

Publicité