Scope of supply
IR heat radiator with mains lead
Mounting bracket including fastenings (supplied)
Manual
Installation instructions
• The S2 infrared radiator 2500 W with multi-point switch (IR05007-WSI) may
only be installed and operated horizontally!
• If radiator and socket are not installed on the same surface, it must be ensured
that the field of radiation cannot be directed towards the socket. Failing this, it
must be ensured that the socket cannot heat up to more than 70°C during heater
operation.
• The safety distances given in Appendix 2 must be observed.
• The area in which the heat acts can be estimated from the radiation diagram
(Appendix 3). The diagram shows the sizes of the irradiated areas at various dis-
tances from the radiant heater and in each case the maximum radiation intensity.
• Installation height: at least 1.80 m above the ground
• The radiator must be installed with the hammer groove upwards.
• The hammer groove can be seen opposite to the connecting lead in view of the
housing side.
101
During mounting
always up
During mounting
always down
10/2017