Télécharger Imprimer la page

Craftsman 919.724110 Guide De L'utilisateur page 16

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
Performing repairs may expose voltage sources, moving
parts or compressed air sources, moving parts or
compressed air sources. Personal injury may occur. Prior to attempting
any repairs, unplug the air compressor and bleed off all air tank air
pressure.
PROBLEM
Air Leaks
Hose fitting loose.
Compressor is
Prolonged excessive use of
not delivering
air.
enough air.
Hole in hose.
Air leaks.
Motor will not
Fuse blown, circuit breaker
run.
tripped.
Extension cord is wrong
length or gauge.
Loose electrical
connections.
Faulty motor.
High discharge
Adjustable pressure valve
pressure.
not functioning.
Cannot be
adjusted lower.
D24483
TROUBLESHOOTING
CAUSE
16- ENG
CORRECTION
Tighten fitting.
Decrease the amount of air
usage. Your compressor is
not large enough for the air
requirement.
Replace the hose.
Tighten fittings.
1.
Check fuse box for
blown fuse and replace
as necessary. Reset
circuit breaker. Do not
use a fuse or circuit
breaker with higher
rating than that specified
for your particular
branch circuit.
2.
Check for proper fuse.
You should be using a
"Time Delay" fuse.
3.
Check for low voltage
problem.
4.
Check the extension
cord.
5.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
Check the extension cord.
Check wiring connection
inside terminal box area.
Contact a Trained Service
Technician.
Risk of
bursting. DO
NOT operate the compressor
if this problem exists.
Adjustable pressure valve
must be replaced.

Publicité

loading