18. WATER SOFTENER
UNIT
Depending on the source of the supply,
water
contains
limestone and minerals which are deposited
on the dishes leaving whitish stains and
marks. The higher the level of these
minerals present in the water, the harder
the water is. The dishwasher is fitted with a
water softener unit which, through the use
of
special
regenerating
softened water for washing the dishes. The
degree of hardness of your water can be
obtained from your water supply company.
Regulating the water softener
The water softener can treat water with a
hardness level of up to 90 °fH (French grading)
or 50 °dH (German grading) through 8 settings.
The settings are listed in the table below,
with the relative mains water to be treated.
Water hardness
0
0-5
0-3
1
6-10
4-6
2
11-20
7-11
3
21-30
12-16
4*
31-40
17-22
5
41-50
23-27
6
51-60
28-33
7
61-90
34-50
* The softener unit is set in the factory at
level 4 (S4) as this satisfies the requirements
of the majority of users.
varying
amounts
salt,
supplies
NO
S0
YES
S1
YES
S2
YES
S3
YES
S4
YES
S5
YES
S6
YES
S7
Regulate the setting of your water softener
unit according to the degree of hardness of
of
your water, as follows:
The dishwasher must ALWAYS be off
before start of this procedure.
1. Turn on the dishwasher by pressing the
"ON/OFF" button for about 3 secs.
2. Hold the "PROGRAMME SELECTION"
and "ON/OFF" buttons down for about
5 secs.
3. The message "SETUP" will appear on
the display and the indicator lights of
the "SMART DOOR/EXPRESS" and
"TABS" buttons will be on.
4. Press the "PROGRAMME SELECTION"
button until you select "SOFTENER S4"
(S4 factory level).
5. Parameter adjustment is performed by
pressing the "SMART DOOR/EXPRESS"
(S7 →
S0) and "TABS" (S0 →
S7)
buttons to increase or decrease the
previously set level.
6. Switch off the dishwasher by pressing
the "ON/OFF" for 3 secs. button to
confirm the new setting.
To change the water softener setting again,
follow the same procedure.
WARNING
If you cannot complete the procedure,
turn the dishwasher off by pressing
the "ON/OFF" button and start the
procedure again from the beginning
(STEP 1).
113