4.7
Switching the generating set off
1.
Disconnect the equipment used, taking care to close the cover for the unit's sockets (A9).
2.
For units equipped with a noise deflector (A4), swivel this forward.
3.
Allow the unit to run idle for 1 or 2 minutes.
4.
Set the switch (A7) to "OFF" or "O ": the unit will shut down.
5.
Close the fuel tap (A5).
6.
For units equipped with a noise deflector, return it to its original position.
7.
Ensure the unit is properly ventilated and to avoid any risk of fire, wait for it to be fully cool before covering it and storing it.
Even when the unit is turned off, the engine continues to give off heat.
5 Generating set maintenance
As a safety measure, maintenance should be performed on the generating set regularly and carefully by people who have the
necessary experience and are equipped with suitable tools, in respect of current regulations. The maintenance operations to be
carried out are detailed in the maintenance table. The interval for this is supplied as a guide and for generating sets operating with
fuel and oil which conform to the specifications given in this manual. The maintenance intervals can be shortened depending on the
generating set's operating conditions and requirements. It is important to note that the warranty shall not be valid if generating set
maintenance has not be performed correctly.
5.1
Reminder of use
Ensuring maintenance is performed regularly and correctly will guarantee safety and performance. The oil, filter elements and,
where present, the spark plug, are consumables which must be in good condition for the unit to operate correctly.
Replace them regularly as often as is needed (the reference for ready-to-use maintenance kits is given in the table of
technical specifications where applicable). The warranty becomes void in the event of failure to respect the maintenance
recommendations. For any questions about a special operation, please contact your nearest agent who will advise and help you.
5.2
Maintenance intervals table
The maintenance frequency is given as an indication only and is for devices using fuel and oil complying with the specifications
given in this manual. The maintenance intervals can be shortened depending on the unit's operating conditions and requirements.
Perform the maintenance operations at the indicated due dates even if the number of hours' operation has not been reached. The
warranty will be invalidated if maintenance of the unit has not been performed correctly.
Operation to be carried out:
Clean the unit
Unit
Clean the spark arrester
Replace the spark plug
Oil
Change
Clean the screen filter
Fuel
Clean the sediment
bowl
Clean
Air filter
Replace
Part numbers of parts to be used during maintenance:
5.3
Performing the maintenance operations
1.
Shut down the unit and wait at least 30 minutes for it to cool.
2.
If necessary, remove the unit's side panels, if fitted.
3.
Disconnect the cap(s) from the spark plug(s).
4.
Carry out maintenance in accordance with the information given in this manual and, to avoid the risk of damage to the unit,
only use original parts or their equivalent.
5.
If necessary, carefully refit the side panels.
5.3.1 Topping up the oil
To ensure that the oil service is performed quickly and correctly, the oil must be changed when the engine is warm (start the unit
and allow it to run for a few minutes if necessary).
1.
Place a suitable container under the oil drain screw (A10-B5), then remove the oil dipstick/filler plug (A2-B1) and the oil
drain screw.
2.
After draining completely, carefully refit the oil drain screw.
3.
Use a funnel to top up with oil (using oil which complies with the specifications given in this manual), and regularly check
the level.
The oil level must be between the minimum and maximum marks on the dipstick. If the oil level is too low, keep topping it up. If the oil
level is too high, drain some off.
4.
Refit and tighten the oil dipstick/filler plug.
5.
Wipe away any traces of oil with a clean cloth and check that there are no leaks.
After
3
Every
5 hours
months/
3 months/
50 hours
50 hours
X
X
X
X
X
X
X
17/180
In hours, months or years, whichever comes first
Every
6 months/
100 hours
X
X
X
X
X
X
X
X
X
X
3499231033104
/
3499231001585
/
3499231033203
Every
Every
1 year/
2 years/
200 hours
500 hours
Routine service
Major service
to be carried
to be carried
out by one of
out by one of
our agents.
our agents.
France:
France:
0.806.800.107
0.806.800.107
(call charge)
(call charge)