Installation
2
Lavatory Mounting
Backing Information
Metal Studs
Securely fasten the plywood
A
to at least (3) metal studs
(plywood to equal thickness
of drywall, ½" minimum)
Bradley Corporation • 215-1511 Rev. E; ECM 09-11-0006
All manuals and user guides at all-guides.com
16"
(406mm)
12"
(305mm)
Drywall
25"
(635mm)
Refer to the rough-ins to determine wall
mounting location for optional mixing valve.
Installer may prefer to install the faucet
before mounting the fi xture to the wall.
If necessary, adjust the fi xture height
before securing to the support brackets.
35"
(889mm)
7/14/09
FL-1H, FL-1L
Use
3
" toggle bolts and
8
B
washers to secure the
support brackets to the
plywood (2) places.