Network Registers - ADEUNIS LoRaWAN TEMP Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LoRaWAN TEMP - Guide utilisateur / User guide version V1.2.0
309
High threshold value of the internal
sensor
310
Value of the high threshold hysteresis
of the internal sensor:
311
Low threshold value of the internal
sensor
312
Value of the low threshold hysteresis of
the internal sensor
313
High threshold value of the external
sensor
314
Value of the high threshold hysteresis
of the iexternal sensor:
315
Low threshold value of the external
sensor
316
Value of the low threshold hysteresis of
the exterbal sensor
317
Acquisition period
318
Super-sampling factor
A consistency check will be performed at the time of the registration of the settings via the AT&W command. If one of the following conditions
is verified, the command will return «W»:
• Period of transmission = 0 (register 301) and no active threshold (registers 303 and 305)
• Two active thresholds (registers 303 and 305), and the value of the high threshold is less than the value of the low threshold.

3.4.2 Network registers

The list of registers below allows you to change the behaviour of the product application. This list is accessible in Provider mode following
execution of the ATT63 Provider command.
These registers must be handled with caution because they could cause problems of communication or of non-compliance with the legislation in
force.
Register
201
Spreading Factor (SF) by default
202
Band width
205
Transmission power
Decimal
Decimal
Decimal
Decimal
Decimal
Decimal
Decimal
Decimal
Decimal
Decimal
Description
Default: 300
Min/max: -550 to 1200 (signed value)
Units: tenth of °C
Default: 10
Min/max: 0 of 255 (Unsigned value)
Unit: tenth of °C
Défaut: 300
Min/max: -550 à 1200 (Unsigned value)
Unit: tenth of °C
Default: 10
Min/max: 0 à 255 (Unsigned value)
Unit: tenth of °C
Dfaut: 300
Min/max: -550 à 1200 (Unsigned value)
Unit: tenth of °C
Default: 10
Min/max: 0 to 255 (Unsigned value)
Unit: tenth of °C
Default: 300
Min/max: -550 à 1200 (Unsigned value)
Unit: tenth of °C
Default: 10
Min/max: 0 à 255 (Unsigned value)
Unit: tenth of °C
Default: 10
Min/max : 1 à 255
Unité:
x 1minute if S306=1
x 10 secondes if S306=2
Default: 5
Min/max: 1 à 10
Unit: aucune
Coding
Decimal
Default: 12 (868) or 10 (915) depending on the refe-
rence of the product
Min/max: 4 to 12
Unit: None
Decimal
Default: 0
Possibilities:
• 0=125kHz
• 1=250kHz
• 2=500kHz
Decimal
Default: 14
Min/max: 2 to 14
Units: dBm
Details
61 of 79