LoRaWAN TEMP - Guide utilisateur / User guide version V1.2.0
5. START-UP
5.1. Starting up the product using a magnet
Once the product has been configured and its assembly has been finalised, the product is ready to be started up.
The start-up is carried out using a magnet which you place on the upper part of the product (cf. the diagram below). The magnet must be held
in position for at least 6 seconds so as to confirm the start-up of the product.
Once the LoRaWAN TEMP unit validates its start-up, it immediately transmits status frames followed by a data frame (according the defined
periodicity).
NB : Once the LoRaWAN TEMP unit has started up, it cannot be switched off.
EN
5.2. Replacing the battery
When the low battery indicator is activated (indicator in the frame or flashing of the red LED), it is possible to change the internal battery of the
unit.
It is important to use a battery of the same reference, SAFT LS14500.
Procedure to change the battery:
1.
Open the unit
2.
Remove the battery and replace it with the new one respecting the polarity as indicated on the electronic card
3.
Close the unit
4.
Restart the product with the magnet as for a first start
After this procedure the product will behave as during a first start.
Battery location
+
Position of the magnet for
starting up the product
Disposition of the battery on the card
-
70 of 79