Status
The service indicator lights red.
The service indicator blinks red.
3.7 Items supplied
Combihammer, side handle, operating instructions.
Note
You can find other system products approved for your product at your local Hilti Center or online at:
www.hilti.com.
4 Technical data
4.1 Breaker
When powered by a generator or transformer, the generator or transformer's power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
The information given applies to a rated voltage of 230 V. The data may vary in the event of deviations from
the rated voltage and for country-specific versions. Please refer to the power tool's rating plate for details of
its voltage, frequency, current and input power ratings.
Rated current input
Weight in accordance with EPTA procedure
01/2003
Single impact energy (EPTA-Procedur 05/2009)
4.2 Noise information and vibration values determined in accordance with EN 60745
The sound pressure and vibration values given in these instructions have been measured in accordance
with a standardized test and may be used to compare one electric tool with another. They may be used
for a preliminary assessment of exposure. The data given represents the main applications of the electric
tool. However, if the electric tool is used for different applications, with different accessory tools, or is poorly
maintained, the data may vary. This may significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This may significantly reduce exposure over the
total working period. Identify additional safety measures to protect the operator from the effects of noise
and/or vibration, for example: maintenance of the electric tool and the accessories, keeping the hands warm,
organization of work patterns.
Noise emission values determined in accordance with EN 60745-2-6
Sound (power) level (L
)
WA
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
All manuals and user guides at all-guides.com
Meaning
•
•
•
•
)
WA
)
pA
)
pA
End of service interval – servicing is due. After
the lamp lights up for the first time, the power
tool may continue to be used for several hours
before the automatic cut-out is activated. Return
the product to Hilti Service for servicing in good
time in order to ensure that it is always ready for
use.
A fault has occurred in the tool.
The overheating prevention cut-out has been
activated.
The voltage provided by the electric supply is
too high.
TE 1000AVR
7.6 A
12.5 kg
26 J
96 dB(A)
3 dB(A)
85 dB(A)
3 dB(A)
5