Before starting

WARNING! Note the following before
!

starting:

The machine should be connected to an
earthed outlet socket.
Check that the mains voltage corresponds
with that stated on the rating plate on the
machine. Keep people and animals well
away from the working area.
WARNING! Before drilling, check that all
!
locking screws are tightened well.
Serious accidents can occur if the concrete
core remains in the drill when backing out
the drill motor/drill from the floor, wall or
ceiling.
Make sure that:
The switch is undamaged. If not, the switch must be
replaced by an authorised repairman.
The machine and its equipment are correctly installed:
- The drill is secured properly.
- The stand is firmly attached.
- Secure the machine on the stand using a suitable method.
Wear personal protective equipment. See instructions
under the "Personal protective equipment" heading.
Water cooling is undamaged and connected to the
machine.
12 –
English

STARTING AND STOPPING

Drilling in the ceiling
WARNING! The vacuum plate must never be
!
used for ceiling drilling.
Use a water collector to avoid water
penetrating into the machine. The machine
must be covered with plastic or the like in
order to prevent water penetrating into the
machine, but do not cover the air intakes
and air outlets.
WARNING! A maximum of one extension
!
module may be used.
Check that no one on the floor below can be
injured by falling concrete cores.
Starting
Turn on the water cooling.
Press in the switch fully.
Start to feed the drill bit with the help of the feed handle.

Stopping

WARNING! The drill bit continues to rotate
!
for a while after the motor has been switched
off. Do not stop the drill bit with your hands.
Personal injuries can occur.
Shut down the machine by pressing the power switch.
Cooling
Run the machine unloaded for a minute or two to cool the
motor.