AXIS 233D Installation Guide
Referring to the image for Drop Ceiling Mount, follow these instructions to mount the dome
camera:
1. Locate the position in the ceiling for a 190mm hole to be cut. A template is included
to aid in marking the mounting hole.
2. Cut the hole in the ceiling according to the markings.
3. Insert the inner mounting ring in the ceiling with the screw guides pointing
down.(Figure A)
4. With four long M3 screws, attach inner mounting ring to the outer mounting ring.
5. Attach the safety wire to something structurally strong in the ceiling and to the base
of the camera using an M4 screw and nut.(Figure B)
6. Through the hole in the ceiling connect the Ethernet cable and the power cable to
the connection block (see Power connections, on page 10).
7. Push the dome body up into the installed bracket taking care to align the screw holes
in body (see step 3, on page 4) with the mounting bracket's screw slots. Tighten
screws to lock camera into the bracket.
8. Slip the decoration ring over the dome aligning screw holes with screw slots in
bracket. Use 2 M3 screws to fasten the decoration ring.(Figure C)
9. The hardware installation is now complete, proceed to Assign an IP address, on page
11 to install the AXIS 233D on your network.