4
Technical data
Operating conditions
Operating conditions
Ambient conditions
Climate
Storage
Transport
Operation
Pollution
Degree of protection
Protective insulation
Insulation between incoming bus and ...
l
8200 vector/motec power section
l
Reference earth / PE
l
Terminal X3.1/59
l
Terminal X3.3/20
l
Terminal X3.3/28
Insulation between incoming bus and ...
Outgoing bus
Insulation between outgoing bus and ...
l
8200 vector/motec power section
l
Reference earth / PE
l
Terminal X3.1/59
l
Terminal X3.3/20
l
Terminal X3.3/28
40
IEC/EN 60721−3−1
IEC/EN 60721−3−2
Corresponding to the data of the Lenze standard device used (see
documentation of the standard device).
EN 61800−5−1
IP20 (protection against accidental contact according to NEMA 250 type 1)
l
1K3 (−25 to +60 °C)
2K3 (−25 to +70 °C)
Degree of pollution 2
Type of insulation (acc. to EN 61800−5−1)
Reinforced insulation
Functional insulation
Functional insulation
Functional insulation
Functional insulation
Type of insulation (acc. to EN 61800−5−1)
Functional insulation
Type of insulation (acc. to EN 61800−5−1)
Reinforced insulation
Functional insulation
No electrical isolation
No electrical isolation
Functional insulation