Drain condensate from pressure
vessel (42).
Every 250 operating hours
Replace air intake filter element of
compressor pump.
Every 500 operating hours
Drain oil and fill with fresh oil.
Every 1000 operating hours
Have unit serviced by an authorized
service station. This will extent the
compressor's service life considera-
bly.
Danger of frost
A
Caution!
Frost (< 4 °C) destroys the
pump and accessories as both
always contain water! If there is a
danger of frost, disassemble pump
and accessories and store in frost-
free conditions.
5.2

Machine storage

1.
Switch unit OFF and unplug.
2.
Release pressure from tank and all
connected air tools.
3.
Store machine in such way that it
cannot be started by unauthorized
persons.
A
Caution!
Do not store machine unpro-
tected outdoors or in damp environ-
ment.
Do not lay device on its side for trans-
portation or storing.

6. Trouble Shooting

A
Danger!
Prior to all servicing:
 Switch Off.
 Unplug.
 Wait until the compressor has
come to a complete stop.
 Ensure the compressor and all air
tools and accessories connected
to it are relieved from pressure.
 Let the device and all air tools
and accessories used cool off.
After all servicing:
 Check to see that all safety
devices are operational.
 Make sure that no tools or other
parts remain on or in the
machine.
Compressor does not run:
No mains voltage.
 Check cables, plug, outlet and
mains fuse.
42
Mains voltage too low.
 Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
machine.
Compressor was stopped by
unplugging.
 Switch compressor OFF at the
On/Off switch, then ON again.
Motor has overheated, caused by
insufficient cooling (cooling fins cov-
ered).
 Turn compressor OFF at the On/
Off switch. Remove cause for
overheating and allow to cool
down for approx. 10 minutes,
then start again.
Compressor runs but does not build
up sufficient pressure.
Condensate drain of pressure ves-
sel leaky.
 Check gasket of drain cock(s);
replace if necessary.
 Tighten drain cock(s) fingertight.
Check valve leaky.
 Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
Pressure regulator not opened wide
enough.
 Open pressure regulator more.
Hose connection between compres-
sor and air tool leaky.
 Check air hoses, replace defec-
tive parts if necessary.

7. Repairs

A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
ENGLISH

8. Environmental Protection

Danger!
A
The condensate from the pres-
sure vessel contains oil residue. Dis-
pose of the condensate environmen-
tally safe by taking it to a proper
collecting point!
A
Danger!
Dispose of the pump's crank-
case oil environmetally safe by taking
it to a proper collecting point!
The machine's packaging can be 100 %
recycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.