Remove the control panel.
Remove screws A which connect to the main pipe. (Fig. 6).
Undo the joints B C and D (for the burner, pilot and thermocouple).
Replace the component. Suitable thread torques are:
Ensure that the appliance is COMPLETELY SEALED
IMPORTANT NOTE:
∗
It is vital for the flue pipe not to get blocked, not even partially, for proper burner operation.
∗
The replacement of any functional component that can affect the safety of the appliance must be
carried out by an AUTHORISED TECHNICIAN.
∗
As a general rule, whenever an operating component is replaced, you must check that the gas mains
tap is shut and that is no fire in the vicinity of the appliance.
4.-ENVIRONMENTAL PROTECTION RECOMMENDATION
On ending its useful life, this product must not be thrown away in a standard rubbish bin, but must be left
in an electrical waste and electronic equipment collection point for recycling.
This is confirmed by the symbol on the product, user manual or packaging.
Depending on the symbol, the materials can be recycled. By recycling and other ways of processing
electrical waste and electronic equipment you can significantly contribute to protecting the environment.
Contact your local authorities for more information of the nearest collection point.
To preserve the environment at the end of the useful life of your product, leave it in the appropriate
places in accordance with the current legislation.
NOTE: THE FINAL HOLDER OF THE CONTAINER WASTE IS RESPONSIBLE FOR ITS
MANAGEMENT.
This appliance is only for professional usage and must be
used by qualified personnel.
Substitution of the thermostatic tap.
Union nut to burner pipe:
Union nut to pilot pipe:
Union nut to thermocouple:
2.5 Kpm
52
0.8 Kpm
0.4 Kpm