Tap thermostatic valve.
When the grille reaches the selected temperature, the burners go to the minimum position. Likewise, as soon as the
temperature drops below the selected value, the burners turn on.
IT IS EXTREMELY IMPORTANT NOT TO OBSTRUCT THE FLUE PIPE.
Valve tap.
The burners are started up manually.
Safety valve.
If the burners and pilot were to turn off accidentally, the safety valve in the thermostat of valve tap would
start to work automatically, closing the gas flow in approximately 20 seconds.
Fat collection.
These appliances are equipped with a simple system to collect fat produced during use.
The fat or oil first drains towards the channel at the front, through a hole in this channel and then falls into
a container. Empty it regularly.
DAILY CLEANING
For the appliance to operate and perform like new, it is advisable to follow the instructions detailed
below.
u)
It is recommended to clean the grille plate at the end of the day.
v)
The use of water and soap is sufficient for cleaning. Never use gritty detergents or abrasive products.
w) It is not advisable to use water hoses to clean the appliance as they may damage its operating
components.
x)
It is advisable to clean the fat collector container once a day in a bowl of hot soapy water.
Never use products with bleach (hydrochloric, perchloric, formic and trichloroacetic acid, amongst
others) nor certain alkaline solutions (sodium hydroxide, for example) to clean the chrome grille.
Special care must also be taken when cleaning the areas near to the grille with abrasive products. If
necessary, cover the appliance, to prevent corrosive products from splashing onto the grille.
List of operating components.
16. Thermostatic valve or gas valve tap "VM"
17. Pilot "P"
18. Thermocouple "T"
Operation
3.-MAITENANCE: