The positioning and electrical and gas installation should always be carried out by an AUTHORISED
TECHNICIAN, observing the standards of each country.
It is advisable to install an extraction hood for the optimum operation of the appliance.
Place the appliance in a well-ventilated place.
Level and adjust the height of the appliance. (Fig. 1)
The appliances can be installed on top of a low unit.
Gas connection
An Authorised Technician, observing the regulations in each country, must always carry out the
appliance's gas connection.
The general installation must have a stopcock and a pressure regulator and it is also advisable to install a
shut-off cock on each individual appliance.
For Liquid Petroleum Gas (L.P.G.) and Natural Gas the appliance should be connected to the mains as
shown in Figure 5
The appliance's gas inlet is labelled G in the diagrams on page 1.
If the appliance is prepared for a different type of gas to the one available in the installation, you should
proceed as follows:
Cut off the gas to the appliance if connected. (Any conversion of the appliance's gas circuit must always be
carried out by a QUALIFIED TECHNICIAN).
To adjust your appliance to work with a different type of gas, proceed in the following way:Turn the
appliance off at the mains (if it is connected).
Burner conversion
Injector replacement.
Dismantle the burners' "A" injectors (Fig. 2) and replace them with suitable ones depending on the gas to
be used (Table 3)
Burner air adjustment.
Position the air regulator "B" (Fig. 2) to the "H" measurement (Table 3) depending on the gas to be used.
Pilot conversion and adjustment
To convert to NATURAL GAS, please proceed as follows: Loosen screw "A" (Fig. 3, DETAIL A).
The 0.25 mm injector "B" is underneath screw "A" which must be loosened and replaced by the 0.40 mm
injector supplied with the nozzles.
Turn the air regulator "C" until the flame steadies (Fig. 3).
To convert to TOWN GAS, the pilot flame adjustment is carried out turning the adjusting screw "B" until the
flame is stable. IMPORTANT NOTE: Any adjustment or replacement should be carried out by an AUTHORISED
TECHNICIAN