Valve tap minimum flow rate adjustment.
To adjust the minimum flow of the gas tap, the burner must have been on for at least 15 minutes and then
the F adjusting screw pressed down completely in the case of G.L.P. or by adjusting this screw,
anticlockwise until a stable flame is achieved, in the minimum for Natural Gas and Town Gas (Fig. 4).
After adapting the equipment to another type of gas or to another pressure, other than that for which it had
been previously set, the old instructions should be replaced with the instructions for the new settings, to
enable unambiguous identification of the state of the equipment after modification.
When the appliance has been installed, clean the surface of the grille. Use water and detergent, do not
use abrasive products. When cleaning, cover the grease exit hole.
Do not use water hoses to clean the appliance.
Burner ignition
Thermostatic valve
s)
Open the gas mains tap.
t)
Press and turn the thermostatic valve control clockwise to the PILOT position (∗).
u)
Keep the control pressed whilst igniting the pilot for approximately 20 seconds until the flame is
stable.
v)
The appliance has a hole at the front for manually igniting the pilot.
w) Now, to turn the burner on, turn the control of the thermostatic valve anticlockwise to the required
position depending on the temperature you want to reach. TABLE 5.
x)
If the control is positioned at 1, OFF (•) the appliance will stop working.
Valve tap
s)
Open the gas mains tap.
t)
Lightly press the gas mains tap control to unlock it and turn it anticlockwise to position 2 (PILOT)
u)
Keep the control pressed while igniting the pilot and keep it pressed for 20 seconds until the
flame becomes stable, in order for it to stay on when the control is released.
v)
The appliance has a hole on the front panel for manually igniting the pilot.
w) To ignite the burner, press the control and turn it anticlockwise to position 3 (MAXIMUM), position
4 (MINIMUM). When the required position is reached, stop pressing the control. The burner will
have been ignited by the pilot.
x)
If we position the control at 1 (OFF) the appliance will stop working.
Temperature control.
When the griddle reaches the selected temperature, the burners automatically return to the minimum
setting. In the same way, when the temperature of the griddle drops, the burners ignite once again.
It is essential to ensure that the chimney remains unobstructed.
Safety valve.
If for any reason the pilot burners are accidentally extinguished, approximately 20 seconds later the
safety valve within the thermostat will automatically turn the gas off at the mains.
Grease and fat collector.
These appliances incorporate a simple system which collects unwanted grease and fat.
The grease or fat is first channelled into a tube situated at the front of the appliance, and then, by
means of an opening in the said tube, into the collector tray. This tray should be emptied at regular
2.-USE
Turning the appliance on
intervals.