The all figures are only schematic, and they may be slightly different from the actual
appliances you selected.
Position for Outdoor Unit
Avoid direct sunlight.
•
Away from heat source, steam source, leakage of flammable gas, smoke and dust.
•
Select a place that is away from rain (snow) and has good ventilation.
•
Neighbors will not be affected by the blown wind and noise, or discharged water.
•
The place that is easy to install and service.
•
Mounted on the solid and reliable foundation will not increase noise or shock.
•
To get high cooling performance, make sure the unit's front, rear, left and right sides
•
must be located in an open area.
The outlet is proposed to be in open air, any obstacle will affect the performances.
•
The installing distance must be required as Fig. 2 shows.
•
Tubing Selection
Ensure that the level (height) difference of indoor and outdoor units and the length of tu-
bing meet the requirement In the Table 1.
If the tubing is longer than 7m, but shorter than 15m, refrigerant should be supplemented
according to Table 1.