Warning:
Chemical reaction hazard!
Unit must be thoroughly cleaned of all residue before switching from acid
to alkaline cleaning agents! Pressure vessel will otherwise be damaged by
pitting.
Flushing pressure vessel (refer to flushing pressure vessel)
Note:
Pressure = 5,5 bar:
Compressor cuts out
Pressure = 4 bar:
Compressor cuts in again
Shampooing/cleaning
Mounting shampoo nozzle (pre-assembled, part of scope of delivery)
Open air supply valve (position in direction of flow)
24
Give control valve 2,5 anti-clockwise turns.
Set ONN/OFF switch to „I".
Allow operating pressure to build up (compressor cuts out).
Actuate hand gun.
Note:
Set shampooing mode at control valve:
Turning anti-clockwise = Shampoo becomes moister
Turning clockwise = Shampoo becomes drier
Tip:
A longer exposure time makes severe, stubborn soiling easier to remove.
This applies particularly to cleaning of exhaust air ducts, corners and
awkwardly shaped surfaces.
Spraying/disinfection
Mounting fan-jet nozzle (accessory, not part of scope of delivery)
Mount nozzle
Stopping machine
Dissipate pressure
Fit nozzle with cap nut