Conditions UL / CSA selon le rapport
Information
•
Listed as ENCLOSED POWER CONVERSION EQUIPMENT
•
"Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit
protection must be provided in accordance with the Manufacturer Instructions, National Electrical Code and
any additional local codes".
CSA: For Canada: "Integral solid state short circuit protection does not provide branch circuit protection.
Branch circuit protection must be provided in accordance with the Canadian Electrical Code, Part I".
•
"Use 75 °C Copper Conductors Only", or "Use min. 75°C rated Copper Conductors Only", or equivalent.
Higher temperature ratings are acceptable.
•
For installations according to Canadian National Standard C22.2 No. 274:
"For use in Overvoltage Category III environments only." or equivalent.
•
"The device has to be mounted according to the Manufacturer Instructions.", or equivalent.
•
"Maximum surrounding air Temperature 40°C."
•
The devices are not allowed for use in corner grounded supplies, with that the maximum working voltage to
ground is considered to be 277Vac.
Frame
Size
"Suitable For Use On A Circuit Capable Of Delivering Not More Than 10kA rms Symmetrical Amperes, 480 (3-
phase) Volts Max., when Protected by High-Interrupting Capacity, Current Limiting Class RK5 Fuses or faster,
all
rated min. 480 Volts".
This is not applicable for devices with QPD-W Connector.
Suitable For Use On A Circuit Capable Of Delivering Not More Than 10kA rms Symmetrical Amperes, 480 Volt
maximum"
all
"When Protected by Circuit Breaker (inverse time trip type) in accordance with UL 489, min. 480 Volts".
This is not applicable for devices with QPD-W Connector.
"Suitable for motor group installation on a circuit capable of delivering not more than 10kA rms symmetrical
amperes, 480 (3-phase) V max, when Protected by High-Interrupting Capacity, Current Limiting Class
all
or faster,
rated max. 30 Amperes".
If provided with QPD-W Connector the SCCR is max. 5kA with class J fuses or faster.
"Suitable for motor group installation on a circuit capable of delivering not more than 10kA rms symmetrical
amperes, 480 (3-phase) V max, when Protected by Circuit Breaker (inverse time trip type) in accordance with UL
all
489, rated max. 30 Amperes and 480 Volts min."
This is not applicable for devices with QPD-W Connector
1)
(voir le chapitre 7.3.1 "Caractéristiques électriques 3~ 400 V")
1.8 Codes de type / spécificités
Le code de type de l'appareil correspond aux caractéristiques d'équipement. Une identification claire de
l'appareil avec toutes les caractéristiques d'équipement spécifiques au client est uniquement possible
par le biais du numéro de commande ou de série de l'appareil.
1.8.1 Plaque signalétique
Toutes les informations relatives à l'appareil, notamment des informations pour l'identification de
l'appareil sont indiquées sur la plaque signalétique. Celle-ci se trouve à l'avant de la coque supérieure
de l'appareil.