1. DESCRIPTION TANKS
Tanks Comfort V - 2 flange 200 - 300 - 500
C
100 mm
Model
Total capacity
Ø with insulation
Ø without insulation
Height
Height with insulation
Anodo
Thermometer/Probe/Anodo
Electrical resistance/recirculation
Anodo
Thermometer/Probe/Anodo
Cold water inlet
Drain
First Flange
Second Flange
Thermometer/Probe/Anodo
Thermometer/Probe/Anodo
Hot water outlet
Empty weight
Technical data
- Maximum operating pressure: 10 bar exchanger.
- Maximum continuous operating temperature accumulation: 95 °C.
- Testing pressure: 15 bar.
- Inorganic enamelling (vitrification).
- Insulation: in polyester flexible thickness 100 mm.
- Insulation coating SKY Grey PVC.
- In compliance with directive 2014/68/EU, art. 4.3.
- In compliance with DIN 4753.3 and UNI 10025.
8
Q
D
E
F
G
H
I
L
1"1/4
1/2"
1"1/2
1"1/4
1/2"
1"1/2
1"1/4
DN290
DN290
1/2"
1/2"
1"1/4
u.m.
ℓ
A
mm
B
mm
C
mm
mm
D
mm
E
mm
F
mm
G
mm
H
mm
I
mm
L
mm
M
mm
N
mm
O
mm
P
mm
Q
mm
kg
Note: in the sanitary circuit near of the boiler must be installed a safety
valve with calibration maximum = 6 bar and the expansion vessel adapted
to the volume of the sanitary system.
P
A
B
O
N
M
200
300
208
285
700
700
500
500
1215
1615
1280
1680
965
1375
895
1315
725
1010
485
540
415
480
245
235
140
140
345
345
765
810
-
1010
965
1375
Up
Up
70
105
GB
GB
500
490
850
650
1690
1755
1395
1325
1065
595
525
285
165
395
865
1065
1395
Up
145