EXHAUST TUBES CONNECTION
This operation must be effected by qualified staff ,only.
•
The appliance has the possibility to be connected to the
•
fume evacuation chimney in the following ways: Vertical
or Lateral or Rear.
Vertical cpnnection:
− Unscrew and remove the upper tap.
− Now it is possible to connect the exhaust fume tube to the
exhaust fan.
− In this case the curve tube supplies must not be Utilized..
Lateral connection
− Take the curve tube placed into the combustion chamber.
− Unscrew the rear and front screws which fix the side and
remove it..
− Pay the maximum attention to the electrical wirings and
connections.
− Take away the round grate from the side paying attention to
not damage the paint-
− Insert the curve tube onto the exhaust fan, positioning it
laterally.
− Re assemble the side, srew the front and rear screws paying
attention to not dammage the electrical wiring.
Rear connection
− Take the curve tube placet into the combustion chamber.
− Unscrew the rear and front screws which fix the side and
remove it..
− Unscrew and remove the back exhaust cover and remove it,
now unscrew the screws which fix the Back in the zone of
the fume exhaust (lh)
− Pay the maximum attention to the electrical wiring and
connections.. Insert the curve tube onto the exhaust fan,
positioning it towards the back
− Re assemble the back and the side, srew their screws paying
attention to not damage the electrical wiring.
In case that the installation needs the application of a "T" pipe fitting among the appliance and the
exhaust tube, only the rear or lateral exhausts can be utilized.