Insulated Flue
CONNECTION TO FLUE
Connect
the
•
equipment to the flue /
chimney checking that the
exhaust pipe doesn't take
up the free section of flue.
Employ
only
•
equipped with seal gasket.
Limit the use of horizontal
•
tubes ( max 2 meters ) and
curves.
CHIMNEY CAP
The chimney cap should have the following characteristics:
•
It's advisable to read, follow and respect what indicated in the paragraphe 1.1
−
Internal section equivalent with the chimney one
−
Exhaust section exit not lower to the double of the chimney internal one
−
Built in a way to avoid rain, snow or external body entrance, to ensure the right exit
−
of combustion products with any type of wind
Positioned to guarantee the right fumes dispersion especially out of re-flux area.
−
This area has several dimensions and conformations in function of inclination
corner of the covering so it's necessary to apply the minimal highness as indicated
in the following tables:
heating
tubes
39/132