man_P2xx_PH6xx-EU ('22) V3.indd 65
man_P2xx_PH6xx-EU ('22) V3.indd 65
B
INSTALLATION
G
WARNING
Before using the air conditioner it should be left in an upright position
for at least 2 hours.
This unit is portable and can easily be moved from one room to another. In doing
so keep this in mind:
Ensure that the unit is positioned upright and on a level surface.
Do not operate the unit inside the bathroom, shower, or in any other very
humid environment.
Please keep a distance of 50 cm between the unit and the wall or other
objects to ensure proper air circulation.
One end of the hose 7 must be attached to the air outlet 6 at the back of
the unit.
Ensure that the window air outlet 6 has a free flow outside. Close the
window or door as much as possible to prevent outside air from entering the
room.
G
IMPORTANT
The flexible exhaust hose 6 should be less than 1m during operation,
which provides the best performance. This length has been designed
especially according to the specifications of the air conditioner. Do not
use an extension or exchange for a different hose as that may lead to
malfunctioning. The exhaust air must flow freely, any blockage can lead
to overheating of the air conditioner. Take care to prevent any bow or
bend in the exhaust hose.
4
65
20-12-2022 15:57
20-12-2022 15:57