Fault
Possible cause
No dry ice pellets in
Dry ice dosing switched off (with jet pistol
the compressed air
Advanced only), "Dry ice dosing on/off"
jet
button on the jet pistol illuminates red,
display shows "Ice off".
Dry ice container is empty
Dry ice has melted
Vibrator on the dry ice container is not
working
Drive motor of the dosing equipment is
overloaded
Compressed air is exiting into the dry ice
container
Dosing disc in the dosing unit is defective Replace the dosing disc.
Electrical connection
Voltage
Current type
Frequency
Connected load
Protective class
FI safety switch
Leakage current, typ.
Compressed air
Nominal width of hose
Pressure supply (max.)
Pressure supply (min.)
Compressed air consumption
Quality of compressed air
Performance data
Jet pressure (max.)
Diameter of dry ice pellets (max.)
Dry ice consumption
Dimensions
Contents of dry ice container
Width
Depth
Height
Weight with accessories
Weight, operational, with filled dry ice container
Weight of the jet equipment (spray agent hose, spray gun, tool case)
Tyre pressure (max.)
Recoil force of hand spray gun (max.)
Torque of jet pistol (max.), only with angled nozzle
Sound pressure level L
Sound power level L
WA
Uncertainty K
Machine vibrations
Jet pistol
Hose for spraying agent
14
Technical specifications
pA
Remedy
Press the dry ice dosing key on the Ad-
vanced jet pistol.
Refill the dry ice container
Empty the dry ice container and refill it with
fresh dry ice pellets.
Call Customer Service.
Let the dosing thaw
Clean the pressure balance channel in the
dosing equipment.
12
-
EN
V
120
1~
Hz
60
kW
0,6
IPX4
delta I in A
0,03
mA
7,5
Inch
3/4
PSI (MPa)
232 (1,6)
PSI (MPa)
29 (0,2)
ft
/min (m
/min)
70...423 ( 2...12)
3
3
dry, oil-free
PSI (MPa)
232 (1,6)
in (mm)
0,12 (3)
lb/h (kg/h)
66...265 (30...120)
lb (kg)
88 (40)
in (mm)
28,2 (716)
in (mm)
33,5 (850)
in (mm)
43,4 (1102)
lb (kg)
224 (101,5)
lb (kg)
309 (140)
lb (kg)
22 (10)
PSI (MPa)
29 (0,2)
N
100
N
40
dB(A)
114
dB(A)
136
dB(A)
5
m/s²
1,2
m/s²
1,2