Healthy:
Charge:
Internal R=
Rated:
2. Cranking Test
2.1
Before Test
The engine and all other accessory loads must be
have accurate results.
2.2
Steps
1) Connect the RED (+) Positive Battery Clamp to the (+) positive battery terminal,
and connect the BLACK (-) Negative Battery Clamp to the (-) negative battery
terminal. Ensure that the clamps are securely attached to the correct terminals.
2) Press the "M" button to display the Main Menu, and select the
1. Batte ry Test
2. Cranking T est
3. Cha rging Test
4. Review Dat a
5. Language
3) Press"Enter"to initiate "Cranking Test" interface, start the engine according to
the prompts
4) The result will show as below,
6
Battery Test
0 %
00CCA
61%
12.37V
39.52m Ω
100A
REPLACE
OFF
in order to
"2. Cranking
Main Menu
Cranking Voltage
>=10.5V
9.9V~10.5V
9.5V~9.9V
<9.5V
Test":
3. Charging Test
3.1
Before Test
The engine must be
3.2
Steps
1) Connect the RED (+) Positive Battery Clamp to the (+) positive battery terminal,
and connect the BLACK (-) Negative Battery Clamp to the (-) negative battery
terminal. Ensure that the clamps are securely attached to the correct terminals.
2) Press the "M" button to display the Main Menu, and select the
3) Press "ENTER" to conduct a "Ripple Test":
Cranking Test
TIME
1024ms
CRANKING
NORMAL
10.12V
Reference Table (for 12V battery)
Discharge Performance
Good
No Action Needed
Not Bad
Bad
Very Bad
ON
during test.
Main Menu
1. Batte ry Test
2. Cranking T est
3. Char ging Test
4. Review Dat a
5. Language
RIPPLE TEST
12.98V
Actions
Recharging
Replace
Replace ASAP
"3. Charging
Test":
7