Télécharger Imprimer la page

Hansgrohe Vernis Blend Pressure Balance 04952 0 Serie Instructions De Montage / Mode D'emploi / Garantie page 2

Publicité

English
Technical Information
Water pressure
recommended
maximum
Hot water temp.
recommended
maximum
04952xx0, 04958xx0 2.5 GPM (9.5 L/min)
04953xx0, 04959xx0 1.75 GPM (6.6 L/min)
04954xx0, 04960xx0
* Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
Installation Considerations
• This trim is for use with iBox Universal Plus model
01850181 (not included).
• For best results, Hansgrohe recommends that
this unit be installed by a licensed, professional
plumber.
• Please read over these instructions thoroughly
before beginning installation. Make sure that
you have all tools and supplies needed to
complete the installation.
This set is for a one-function (showerhead
only) installation. Do not attempt to add a second
function.
• This pressure balance valve is for use with shower
heads rated at 1.1 GPM (4.2 L/min) or higher.
• #04952xx0/#04958xx0 only:
This showerhead is intended for use with an
automatically compensating valve rated at 1.9
GPM (7.2 L/min) or less.
• #04953xx0/#04959xx0 only:
This showerhead is for use with automatic
compensating valves rated at 1.3 GPM (4.9
L/min) or less.
• #04954xx0/#04960xx0 only:
This showerhead is for use with automatic
compensating valves rated at 1.1 GPM
(4.2 L/min) or less.
2
15 - 75 PSI (0.1-0.5 MPa)
145 PSI (1 MPa)
120°-140° F (49°- 60°C)*
158°F (70° C)*
1.5 GPM (5.7 L/min)
• To prevent scald injury, the maximum output
temperature of the shower mixing valve must be
no higher than 120°F (49°C). In Massachusetts,
the maximum output temperature can be no
higher than 112°F (44°C).
• Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.
The rotational limit stop (see page <?>)
Adjust the rotational limit stop if:
• The maximum output temperature is greater
than 120°F (49°C) or that permitted by local
plumbing code.
• The temperature of the incoming hot or cold
water supply changes seasonally, or if changes
are made to the water heater.

Publicité

loading