Smaller distances to combustible materials are permissible if it is ensured that at the
rated performance of the fireplace the temperature cannot rise over 85°C at the
combustible equipment and furnishings.
WARNING:
The connection of the fireplace to the chimney is not permissible if the effective height of
the chimney is less than 4 m, or 5 m with multiple loading (see the details of chimney
calculations on 3.).
To the chimney that the fireplace uses, a maximum of two other fireplaces, ovens may
be connected.
How to connect the Ø 120 mm rear pipe:
1. Remove the top flue pipe stub and the backside cover plate.
2. Mount the rear closing cap of the flue opening tightly on the top.
3. Place the supplied coating plate (see ash-box) on it.
4. Tightly screw the flue pipe stub on the backside.
The fireplace can usually be
connected to the chimney with
an angle pipe
With weak chimney draught, the
fireplace is to be connected to
the chimney through a vertical
flue
gas
pipe
discharge.
34
facilitating