2. Placing
2.1 Prescriptions
For setting purposes and connection to the chimney, the fire protection requirements as
prescribed
in
DIN 4705, DIN 18896, DIN 18160, EN 13384, EN 1856-2 and EN 15287 should be
complied with. For the problem-free functioning of the equipment, the chimney that the
fireplace is to be connected to has to be in perfect conditions (mainly Germany).
2.2 Place of installation
As the air needed for burning is drawn from the room where the fireplace is located,
ensure that sufficient air supply is received via the gaps by the windows and external
doors. Make sure that 4 m
For this fireplace, it means that the room has to be at least 32 m in volume. If the room
is smaller, sufficient air supply can be secured by opening air connections to other
rooms with air openings (at least 150 cm
2.3 Distances
All the combustible materials, furniture or e.g. decoration materials that are in the close
environment of the fireplace should be protected from the heat.
Furnishing in the radiation area
Keep a minimal distance of 100 cm (A) between the front edge of the fireplace and the
combustible equipment, furniture or e.g. decoration materials in the building. The
security distance can be reduced to 50 cm (B) if a heat shield is placed in front of the
object to be protected (see example in Picture 7).
Furnishing beyond the radiation area
The walls beside and behind the fireplace may not be made of combustible materials,
and they cannot be covered with such materials if the distance on the sides is under
50 cm, or 50 cm on the rear side. Similarly, the distance to wooden and plastic
furniture on the sides should be at least 50 cm (see Picture 8).
the
given
3
of air should be provided to each kW of rated performance.