Filling quantities
-
Split billet: max. Length: 33 cm, Ø 5 - 12 cm, max.2-3 billet per filling, max. 1,8 kg
- Lignite briquette: max. 2,1 kg
1.2 Installation
Fuels
The equipment can be used with fuels detailed in the followings. This way the "low-
smoke" and trouble-free operation can be secured. Use only dry wood with moisture of
maximum 20% and brown coal briquette.
Types of fuels
Hard wood
Soft wood
Brown-coal
pic.2
Heating value appr. kJ/kg
19.500
14.600
11.500
Table 1
closed
open
26
Primary air regulator "A"
Fuel selector "B"