38
38: "Analysis Error - Error in motor task list during fill up post script.",
39
39: "Biosensor removed during fill-up sequence, aborting analysis.",
40
40: "Cartridge forcibly ejected during fill-up sequence, aborting analysis.",
41: "Biosensor removed, aborting start of analysis.",
41
42: "Cartridge forcibly ejected, aborting analysis.",
42
43
43: "Find Piston Error - Error in motor task list during find piston.",
44
44: "Timed out during Pre-Use Check while waiting for measurement data.",
45
45: "Biosensor Channel {channel} limit test failed, value: {ncurrent}.",
46
46: "Could not fully retract motors, remove cartridge carefully by hand and contact service.",
47
47: "Date/Time for MD Unit set incorrectly ({timestamp}), contact service.",
48: "Error during initialization of motors, contact service.",
48
49: "Flush Error - Error in motor task list.",
49
50: "Biosensor removed during flush, aborting analysis.",
50
51
51: "Cartridge forcibly ejected during flush, aborting analysis.",
52
52: "Could not fully retract motors, remove cartridge carefully by hand.",
53
53: "Could not fully retract motors.",
54
54: "Could not fully retract motors, aborting test mode.",
55
55: "Error in task list ID {task_list_id}: {task_list_errors}.",
56: "Error in task {task_motor_name} / {task_task_name}: {task_errors}.",
56
57: "Error in battery info thread: {e}.",
57
58: "Biosensor data signal missing check failed.",
58
59
59: "{key}: Signal missing - max value last {duration}s: {ncurrent} nA below limit {limit_na} nA.",
60
60: "{key}: Signal too high - average value last {duration}s: {ncurrent} nA over limit {limit_na} nA.",
61
61: "Biosensor data short circuit check failed.",
62
62: "Temperature below allowed low limit ({limit_low}) - average value last
(temperature_sanity_length} measurements: {avg_temp:.2f}°C.",
63: "Temperature above allowed high limit ({limit_high}) - average value last
63
{temperature_sanity_length} measurements: {avg_temp:.2f}°C.",
64
64: "Unable to get channel average ncurrent: {e}.",
65
65: "Resetting MD Amplifier by power cycle...",
66
66: "Already tried resetting MD Amplifier once, temperature cannot be read.",
67: "Pre-Use Check Failed, values: {channel_data}.",
67
68: "Error quering the max date: {e}.",
68
69: "Error inserting into database: {e}.",
69
70: "Unable to parse request data: {json_data}, error: {e}.",
70
71
71: "Unknown LogMessage level: {log_message}.",
72
72: "Unable to parse push data: {data}, error: {e}.",
73
73: "Socket Event Handler Exception: {e}, Event Data: {event_data}",
74
74: "Invalid socket request received: {request}.",
75: "Socket Request Handler Exception: {e}.",
75
76: "ADS1254 Driver: Unable to read at least 1 sample.",
76
77: "ADS1254 Driver: Max read sample attempts reached.",
77
78
78: "ADS1254 Driver: Error reading from ADC - {e}.",
79
79: "ADS1254 Driver: Read bits timeout, couldn't find DREADY signal pattern.",
80
80: "Exception: {e}.",
81
81: "Unable to merge user settings with default settings: {e}.",
82
82: "Could not copy fallback file to destination: {e}.",