6.2
Storage conditions
In the event that the generating set is not to be used for a long period, respect the following procedure for storing the generating set
in order to prevent any damage. The generating set should be stored in its normal operating position; never lay it on its side.
Drain the fuel and change the engine oil :
1.
Start the generating set and leave it running until it runs out of fuel.
2.
With the generating set still warm, change the engine oil.
3.
Replace the fuel filter (C1), leaving the remaining fuel to drain out completely into a suitable recipient.
4.
Close the fuel taps (A6).
Lubricate the cylinders and the valves:
5.
Remove the cap from the spark plug (F1) and the spark plug (A16-F2
6.
Pour approximately one teaspoon of engine oil in through the spark plug opening before refitting the spark plug.
7.
Pull the starter-recoil reel handle (A10) several times to distribute the oil inside the cylinders.
Disconnect the battery:
8.
First disconnect the red cable (+) then the black cable (-) from the battery.
9.
Remove the mountings from the battery, then remove the battery (A2)
10. Store in a clean, dry location and check the charge regularly to maintain a constant voltage.
Store the generating set:
11. Clean the outside of the generating set with a cloth and apply an anti-rust product to the damaged areas.
12. Cover the generating set with a protective cover and store it in a clean, dry and well-ventilated place.
This procedure for storing the generating set or protecting it over the winter must be respected if the generating set is not used for a
period of up to 1 year. For longer periods of storage, it is recommended to contact your nearest agent or to start up the generating
set for a few hours every year, and respect the storage procedure after doing so.
7.1
Diagnostics for minor faults
The unit...
Does not start
Stops
Does not function normally
(noise, smoke, etc.)
Does not supply electrical
current
1132_EN.docx
Check that:
The checks before starting have been
performed.
YES
The start-up procedure has been
followed correctly.
YES
The equipment to be used has not
been connected prior to starting.
YES
The battery is correctly connected and
charged.
YES
The spark plug(s) are in good condition
and correctly connected.
YES
The oil level is correct.
YES
The fuel level is correct.
YES
Maintenance has been correctly
performed on the unit components.
YES
Have the unit checked by one of our
agents*.
The circuit breaker(s) has/have been
tripped.
YES
The connected equipment and their
power cords are not faulty.
YES
Have the unit checked by one of our
agents*.
22/226
Section 7. Repairing minor faults
Solutions to be applied:
Perform the necessary checks.
NO
Re-read the start-up procedure and repeat
the start-up attempt.
NO
Disconnect the equipment then try to start
the unit again.
Install the battery; replace it with a new
battery if necessary.
Replace the spark plug (330830012).
NO
Top up with oil.
NO
Fill up with fuel.
NO
Perform maintenance on the unit as per
the recommendations.
NO
Check the capacity of the unit and press
the circuit breaker(s).
NO
Try with another item of equipment and
another power cord.
NO
*France: 0.806.800.107 (call charge).