7. Troubleshooting
A system fault will be indicated by an acoustic signal and one of the following fault codes on
the remote control display:
Display
Fault
E03 E
Overheated coil
E05 E
Temperature increase of less than
1 °C (1.8 °F) every 15 seconds
(or 1 °C (1.8 °F) every 30 seconds)
E06 E
Temperature probe not connected
(or defective) or excessive
temperature drop
E10 E
Electronics communication problem
E11 E
Electronics communication problem
E12E
Electronics communication problem
14
Action
Wait until the inductive coil cools.
Switch the heater OFF and then
back ON
Check the temperature probe
connection. If the connection is OK,
select the 30 second interval as
described in section 6 or operate
the heater in TIME MODE
Check the temperature probe
Switch the heater OFF and then
back ON. If problem remains return
the TIH to SKF for repair
Switch the heater OFF and then
back ON. If problem remains return
the TIH to SKF for repair
Switch the heater OFF and then
back ON. If problem remains return
the TIH to SKF for repair
SKF TIH 100m