Chapter 3 - TERMINAL BOARD POINTS
3.1 DIGITAL INPUTS TERMINAL BOARD POINTS
Connectors XDI0 and XDI1 have different ground connection.
Connector
Terminal
Function (Fw 1.X ) Digital input 5 Digital input 6 Digital input 7 Digital input 8 GND
Function (Fw 2.X )
Connector
Terminal
Function (Fw 1.X )
Function (Fw 2.X )
Connector
Terminal
Function (Fw 1.X )
Function (Fw 2.X )
n.a. : not available
3.2 DIGITAL OUTPUTS TERMINAL BOARD POINTS
Digital outputs need a +15V...+24V supply voltage. The Drive TB can be used
to supply 24VDC power. AV-300i 24VDC supply maximum output = 120 mA
total including Encoder, LAN, EXP card and DGF (or 350 mA without DGF).
Terminal 60 is power supply, terminal 55 is the common power supply.
Connector
Terminal
Function (Fw 1.X ) Digital output 3 Digital output 4 Digital output 5 COM Digital output 6
Function (Fw 2.X )
Terminal
Function (Fw 1.X ) Digital output 7 Digital output 8
Function (Fw 2.X )
n.a. : not available
—————— I/O Expansion card ——————
D20A6
DIGITAL INPUTS
31
32
DI0X
DI1X
36
37
n.a.
n.a.
DI4X
DI5X
41
42
n.a.
n.a.
DI8X
DI9X
DIGITAL OUTPUTS
51
52
DO0X
DO1X
56
57
DO4X
DO5X
XDI0
33
34
DI2X
DI3X
XDI1
38
39
n.a.
n.a.
DI6X
DI7X
XDI0
43
44
n.a.
n.a.
DI10X
DI11X
XDQ
53
54
DO2X
COM
58
59
n.a.
n.a.
DO6X
DO7X
35
GND
40
GND
GND
45
GND
GND
expDA10
55
DO3X
60
PWR
PWR
expDA20
15