Télécharger Imprimer la page

Publicité

Liens rapides

All manuals and user guides at all-guides.com
D20A6 expanded I/O
for AV-300i Drives
12 Digital Inputs
8 Digital Outputs
2 Analog Inputs
2 Analog Outputs (V)
2 Analog Outputs (I)
INSTRUCTIONS
GE Industrial Systems
GE Industrial Systems

Publicité

loading

Sommaire des Matières pour GE D20A6

  • Page 1 INSTRUCTIONS All manuals and user guides at all-guides.com GE Industrial Systems GE Industrial Systems D20A6 expanded I/O for AV-300i Drives 12 Digital Inputs 8 Digital Outputs 2 Analog Inputs 2 Analog Outputs (V) 2 Analog Outputs (I)
  • Page 2 If further information is desired or if particular problems arise that are not covered sufficiently for the purchaser’s purpose, the matter should be referred to GE Industrial Systems, Salem, Virginia, USA. This document contains proprietary information of...
  • Page 3 All manuals and user guides at all-guides.com SAFETY SYMBOL LEGEND / LÉGENDE DES SIGNES DE SÉCURITÉ ARNING Commands attention to an operating procedure, practice, condition, or statement which, if not strictly observed, could result in personal injury or death. Attire l’attention sur les modes d’utilisation et les procédés et conditions d’exploitation qui, en cas d’inobservation, pourraient entraîner des blessures corporelles ou la mort.
  • Page 4 All manuals and user guides at all-guides.com...
  • Page 5 D20A6 All manuals and user guides at all-guides.com Table of Contents SAFETY SYMBOL LEGEND / LÉGENDE DES SIGNES DE SÉCURITÉ ................3 Chapter 0 - SAFETY PRECAUTIONS / PRECAUTIONS DE SECURITÉ ................6 Chapter 1 - INTRODUCTION ............. 12 Chapter 2 - MOUNTING ............14 Chapter 3 - TERMINAL BOARD POINTS ........
  • Page 6 GEI-100427A All manuals and user guides at all-guides.com Chapter 0 - SAFETY PRECAUTIONS / PRECAUTIONS DE SECURITÉ The terms “Inverter”, “Controller” and “Drive” are sometimes used interchangably throughout the indus- try. We will use the term “Drive” in this document Les mots “Inverter”, “Controller”...
  • Page 7 D20A6 All manuals and user guides at all-guides.com 89/392/EEC concernant le secteur de l’industrie. Les systèmes provoquent des mouvements mécaniques. L’utilisateur est responsable de la sécurité concernant les mouvements mécaniques. Les dispositifs de sécurité prévues par l’usine et les limitations operationelles ne doivent être dépassés ou modifiés.
  • Page 8 GEI-100427A All manuals and user guides at all-guides.com Drives should be installed away from hazardous areas, even if used with motors suitable for use in these locations. L’utilisation des drives dans des zônes à risques (présence de vapeurs ou de poussières inflammables), peut provoquer des incendies ou des explosions.
  • Page 9 D20A6 All manuals and user guides at all-guides.com ! / P AUTION RECAUTION Do not connect power supply voltage that exceeds the standard specification voltage fluctuation permissible. If excessive voltage is applied to the Drive, damage to the internal components will result.
  • Page 10 GEI-100427A All manuals and user guides at all-guides.com A capacitative load (e.g. Var compensation capacitors) should not be con- nected to the output of the frequency inverter (terminals U2, V2, W2). The electrical commissioning should only be carried out by qualified per- sonnel, who are also responsible for the provision of a suitable ground connection and a protected power supply feeder in accordance with the local and national regulations.
  • Page 11 D20A6 All manuals and user guides at all-guides.com d’enlever des matériaux isolants ou des capots. Protéger l’appareil contre des effets extérieurs non permis (température, humidité, chocs etc.). Aucune tension ne doit être appliquée sur la sortie du convertisseur (bornes U2, V2 et W2). Il n’est pas permis de raccorder la sortie de plusieurs convertisseurs en parallèle, ni d’effectuer une connexion directe...
  • Page 12 All manuals and user guides at all-guides.com Chapter 1 - INTRODUCTION The D20A6 card is an AV-300i drive option used to add digital inputs, digital outputs, analog inputs, analog outputs to the drive. It is possible to use only one I/O expansion card per Drive. This option card features:...
  • Page 13 D20A6 All manuals and user guides at all-guides.com Back side —————— I/O Expansion card ——————...
  • Page 14 The D20A6 card is supplied with standoffs and the cable for connection between regulation and expansion card . Switch the drive off. Fasten the D20A6 card to the drive regulation board by means of screws (B) and standoffs (A). The D20A6 card is connected to the regulator card through the XH connector using the supplied connector.
  • Page 15 D20A6 All manuals and user guides at all-guides.com Chapter 3 - TERMINAL BOARD POINTS 3.1 DIGITAL INPUTS TERMINAL BOARD POINTS Connectors XDI0 and XDI1 have different ground connection. DIGITAL INPUTS Connector XDI0 Terminal Function (Fw 1.X ) Digital input 5 Digital input 6 Digital input 7 Digital input 8 GND Function (Fw 2.X )
  • Page 16 GEI-100427A All manuals and user guides at all-guides.com 3.3 ANALOG INPUTS TERMINAL BOARD POINTS Differential analog inputs are available. ANALOG INPUTS Connector Terminal Function (Fw 1.X ) n.a. n.a. n.a. n.a. An inp 1X + An inp 1X - An inp 2X + An inp 2X - Function (Fw 2.X ) n.a.
  • Page 17 D20A6 All manuals and user guides at all-guides.com 3.5 FUNCTIONAL OVERVIEW 0V (COM) Digital input 5 (DI0X) +24V (PWR) Digital output 3 Digital input (DO0X) (DI1X) Digital output 4 Digital input (DO1X) (DI2X) Digital output 5 (DO2X) Digital input (DI3X)
  • Page 18 GEI-100427A All manuals and user guides at all-guides.com Chapter 4 - JUMPERS Following table describes the expansion board jumpers. JUMPERS ON BOARD Default Name Description Adaption to the input signal of analog input 1 ON 0…20mA / 4…20mA OFF 0…10V / -10V…-10V Adaption to the input signal of analog input 2 ON 0…20mA / 4…20mA OFF 0…10V / -10V…-10V...
  • Page 19 D20A6 All manuals and user guides at all-guides.com Chapter 6 - TECHNICAL DATA Dimensions and Weight 92.36 Dimensions _________________________________ 142.49mm [5.6 inches] x 92.36 mm [3.63 inches] Weight _____________________________________ 77 g [2.7 oz] —————— I/O Expansion card ——————...
  • Page 20 GEI-100427A All manuals and user guides at all-guides.com General Data I/O scan time ________________________________ 2ms Internal power supply from the drive _____________ +5VDC, ±18VDC The Drive TB can be used to supply 24VDC power. AV-300i 24VDC supply maximum output = 120 mA total including Encoder, LAN, EXP card and DGF.
  • Page 21 D20A6 All manuals and user guides at all-guides.com Voltage Analog Outputs Output type _________________________________ Voltage Outputs no. _________________________________ 2 Max Output voltage __________________________ ±10V Output current ______________________________ 5mA max Bandwidth __________________________________ 265Hz Current Analog Outputs Output type _________________________________ Current Outputs no. _________________________________ 2...
  • Page 22 GEI-100427A All manuals and user guides at all-guides.com Chapter 7 - ACCESSORIES Terminals XDI0,XDI1, XDI2, XAI, XAQV, XAQI Type PHOENIX CONTACT 5 contacts MC1,5/5 ST3,81 1803604 or equivalent. Terminals XDQ __________________________ Type PHOENIX CONTACT 10 contacts MC 1,5/10 ST3,81 1803659 or equivalent. Chapter 8 - MAXIMUM WIRE SIZES Terminals on connector XDQ, XDI1, XDI2,XDI3, XAI,XAQV, XAQI...
  • Page 23 All manuals and user guides at all-guides.com...
  • Page 24 All manuals and user guides at all-guides.com 1S5G21 GEI-100427A 001109 SIEI...