4.1 Input polarity
4.2 Activating the 30 Hz filter
4.3 Scaling factor (totaliser)
4.4 Decimal point (totaliser)
All manuals and user guides at all-guides.com
npn: switching to 0 V
pnp: switching to +24 V
max. count frequency
20 kHz
max. count frequency
30 Hz
It can be set from 00.0001
up to 99.9999. The
decimal point is set to 4
decimal places.
„0" won't be accepted!
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0
no decimal place
0.0
one decimal place
0.00 two decimal places
0.000 three decimal
places
4.5 Reset mode (totaliser)
4.6 Scaling factor (tachometer)
4.7 Decimal point (tachometer)
4.8 Display mode (tachometer)
manual reset (red key)
and electrical reset
no reset
(red key and reset input
locked)
electrical reset only
manual reset only
It can be set from 00.0001
up to 99.9999. The
decimal point is set to 4
decimal places.
„0" won't be accepted!
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0
no decimal place
0.0
one decimal place
0.00 two decimal places
0.000 three decimal
places
Calculating and displaying
the value to 1/sec
Calculating and displaying
the value to 1/min
5